Register adresse SMA

Number of contiguous SMA registers

Data type SMA

Data format SMA

Access SMA

Register adresse SunSpec

Name SunSpec

Information model SunSpec

Number of contiguous SunSpec registers

Data type SunSpec

Scaling faktor register SunSpec

Access SunSpec

Unit

Value range

Default value

Grid Guard

Device Control Object

Parameter name for Speedwire/Webconnect and WLAN

Parameter name for RS485

Objekt name SMA

31059

2

U32

TAGLIST

RO

-

-

-

-

-

-

-

-

1129: Yes (Yes)

1130: No (No)

16777213: Information not available (NaNStt)

-

-

-

Absorption phase active

-

Bat.AbsPhsAct

30843

2

S32

FIX3

RO

-

-

-

-

-

-

-

A

-

-

-

-

Battery current

-

Bat.Amp

30987

2

U32

FIX1

RO

-

-

-

-

-

-

-

%

-

-

-

-

Fault battery state of charge

-

Bat.BatChaDif

41281

2

U32

HIDDEN

RW Warnung vor zyklischem Beschreiben

-

-

-

-

-

-

-

-

3643: 44V (44V)

3644: 46V (46V)

3645: 48V (48V)

-

-

-

Nominal battery voltage

-

Bat.BatVTyp

40031

2

U32

FIX0

RO

40259

AhrRtg

120

1

uint16

40260

RO

Ah

0 Ah to 10000 Ah

-

-

-

Battery nominal capacity

-

Bat.CapacRtg

40187

2

U32

FIX0

RO

40257

WHRtg

120

1

uint16

40258

RO

Wh

0 Wh to 2147483.647 Wh

-

-

-

Battery nominal capacity

-

Bat.CapacRtgWh

31061

2

U32

TAGLIST

RO

-

-

-

-

-

-

-

-

1129: Yes (Yes)

1130: No (No)

16777213: Information not available (NaNStt)

-

-

-

Control of battery charging via communication available

-

Bat.ChaCtlComAval

34669

2

U32

TAGLIST

RO

-

-

-

-

-

-

-

-

1129: Yes (Yes)

1130: No (No)

16777213: Information not available (NaNStt)

-

-

-

Control of battery charging via communication available

-

Bat.ChaCtlComAval

30845

2

U32

FIX0

RO

40378

ChaState

124

1

uint16

40392

RO

%

-

-

-

-

Current battery state of charge

-

Bat.ChaStt

40717

2

U32

FIX3

RW Warnung vor zyklischem Beschreiben

-

-

-

-

-

-

-

Ohm

0 Ω to 0.100000 Ω

-

-

-

Output resistance of battery connection

-

Bat.DcRis

30847

2

U32

FIX0

RO

-

-

-

-

-

-

-

%

0 % to 200 %

-

-

-

Current battery capacity

-

Bat.Diag.ActlCapacNom

30857

2

S32

FIX0

RO

-

-

-

-

-

-

-

-

-

-

-

-

Number of battery charge throughputs

-

Bat.Diag.CapacThrpCnt

30993

2

U32

FIX3

RO

-

-

-

-

-

-

-

-

0  to 2 

-

-

-

Charge factor: ratio of battery charge/discharge

-

Bat.Diag.ChaFact

30989

2

U32

FIX3

RO

-

-

-

-

-

-

-

A

-2147483.647 A to 2147483.647 A

-

-

-

Maximum battery current in charge direction

-

Bat.Diag.ChaAMax

30991

2

U32

FIX3

RO

-

-

-

-

-

-

-

A

-2147483.647 A to 2147483.647 A

-

-

-

Maximum battery current in discharge direction

-

Bat.Diag.DschAMax

30995

2

U32

Dauer

RO

-

-

-

-

-

-

-

s

0 s to 1036800000 s

-

-

-

Operating time of battery statistics counter

-

Bat.Diag.StatTm

30997

2

S32

TEMP

RO

-

-

-

-

-

-

-

°C

-40 °C to 100 °C

-

-

-

Lowest measured battery temperature

-

Bat.Diag.TmpValMin

30999

2

S32

TEMP

RO

-

-

-

-

-

-

-

°C

-40 °C to 100 °C

-

-

-

Highest measured battery temperature

-

Bat.Diag.TmpValMax

30567

2

U32

FIX0

RO

-

-

-

-

-

-

-

Ah

-

-

-

-

Amp hours counter for battery charge

-

Bat.Diag.TotAhIn

30569

2

U32

FIX0

RO

-

-

-

-

-

-

-

Ah

-

-

-

-

Amp hours counter for battery discharge

-

Bat.Diag.TotAhOut

31001

2

U32

FIX2

RO

-

-

-

-

-

-

-

V

-

-

-

-

Max. occurred battery voltage

-

Bat.Diag.VolMax

31003

2

U32

Dauer

RO

-

-

-

-

-

-

-

s

-

-

-

-

Remaining time until full charge

-

Bat.FulChaRmgTm

31005

2

U32

Dauer

RO

-

-

-

-

-

-

-

s

-

-

-

-

Remaining time until equalization charge

-

Bat.EqChaRmgTm

40533

2

U32

TAGLIST

RW Warnung vor zyklischem Beschreiben

-

-

-

-

-

-

-

-

381: Stop (Stop)

1466: Wait (Wait)

1467: Start (Str)

-

-

-

Manual equalization charge

-

Bat.Operation.EqChaMan

30955

2

U32

TAGLIST

RO

40381
40301

ChaSt
StorConn

124
122

1
1

uint16
uint16

-

RO
RO

-

2292: Charge battery (BatChaStt)

2293: Discharge battery (BatDschStt)

16777213: Information not available (NaNStt)

-

-

-

Battery oper. status

-

Bat.OpStt

40715

2

S32

TEMP

RW Warnung vor zyklischem Beschreiben

-

-

-

-

-

-

-

°C

-

-

-

-

Battery switch-on limit after overtemp. shutdown

-

Bat.OvTmpRstr

31007

2

U32

Dauer

RO

-

-

-

-

-

-

-

s

-

-

-

-

Remaining absorption time

-

Bat.RmgChaTm

40033

2

U32

TEMP

RW Warnung vor zyklischem Beschreiben

-

-

-

-

-

-

-

°C

-

-

-

-

Max. battery temperature

-

Bat.TmpMax

30849

2

S32

TEMP

RO

-

-

-

-

-

-

-

°C

-

-

-

-

Battery temperature

-

Bat.TmpVal

40035

2

U32

TAGLIST

RO

-

-

-

-

-

-

-

-

1782: Valve Regulated Lead Acid battery (VRLA) (BatTypVRLA)

1783: Flooded lead acid batt. (FLA) (BatTypFLA)

1785: Lithium-Ion (Li-Ion) (BatTypLiIon)

-

-

-

Battery type

-

Bat.Typ

30851

2

U32

FIX2

RO

40380

InBatV

124

1

uint16

40394

RO

V

-

-

-

-

Battery voltage

-

Bat.Vol

40037

2

U32

FIX0

RO

-

-

-

-

-

-

-

V

40 V to 48 V

-

-

-

Nominal battery voltage

-

Bat.VRtg

31397

4

U64

FIX0

RO

-

-

-

-

-

-

-

Wh

-

-

-

-

Battery charge

-

BatChrg.BatChrg

31393

2

U32

FIX0

RO

-

-

-

-

-

-

-

W

-

-

-

-

Present battery charge

-

BatChrg.CurBatCha

31401

4

U64

FIX0

RO

-

-

-

-

-

-

-

Wh

-

-

-

-

Battery discharge

-

BatDsch.BatDsch

31395

2

U32

FIX0

RO

-

-

-

-

-

-

-

W

-

-

-

-

Present battery discharge

-

BatDsch.CurBatDsch

40189

2

U32

FIX0

RO

40372
40261

WChaMax
MaxChaRte

124
120

1
1

uint16
uint16

40388
40262

RW Warnung vor zyklischem Beschreiben
RO

W

0 W to 100000 W

-

-

-

Batt. manuf's max. charge capac.

-

BatConv.WMaxCha

40191

2

U32

FIX0

RO

40263

MaxDisChaRte

120

1

uint16

40264

RO

W

0 W to 100000 W

-

-

-

Batt. manuf's max. disch. capac.

-

BatConv.WMaxDsch

40705

2

U32

FIX0

RW Warnung vor zyklischem Beschreiben

-

-

-

-

-

-

-

%

0 % to 90 %

-

-

-

Upper state of charge for reactivating feed-in

-

BatUsDm.ChaSttFeedAct

40707

2

U32

FIX0

RW Warnung vor zyklischem Beschreiben

-

-

-

-

-

-

-

%

-

-

-

-

Lower state of charge for locking feed-in

-

BatUsDm.ChaSttFeedIna

40719

2

U32

FIX0

RW Warnung vor zyklischem Beschreiben

-

-

-

-

-

-

-

%

-

-

-

-

Lower lmt deep disch. protect area prior shutdown

-

BatUsDm.DschProDmLim

40721

2

U32

FIX0

RW Warnung vor zyklischem Beschreiben

-

-

-

-

-

-

-

%

2 % to 50 %

-

-

-

Minimum width of deep discharge protection area

-

BatUsDm.DschProDmMin

40723

2

U32

FIX0

RW Warnung vor zyklischem Beschreiben

-

-

-

-

-

-

-

%

0 % to 100 %

-

-

-

Minimum width of backup power area

-

BatUsDm.BckDmMin

40725

2

U32

FIX0

RW Warnung vor zyklischem Beschreiben

-

-

-

-

-

-

-

%

4 % to 20 %

-

-

-

Area width for conserving battery state of charge

-

BatUsDm.SelfCsmpBrd

40727

2

U32

FIX0

RW Warnung vor zyklischem Beschreiben

-

-

-

-

-

-

-

%

0 % to 100 %

-

-

-

Minimum width of own consumption area

-

BatUsDm.SelfCsmpBrdMin

40729

2

U32

TAGLIST

RW Warnung vor zyklischem Beschreiben

-

-

-

-

-

-

-

-

2624: June profitable (JunMaxYld)

2625: December profitable (DecMaxYld)

-

-

-

Most productive month for battery usage range

-

BatUsDm.MaxYldMth

40731

2

U32

TAGLIST

RW Warnung vor zyklischem Beschreiben

-

-

-

-

-

-

-

-

1129: Yes (Yes)

1130: No (No)

-

-

-

Season operation active

-

BatUsDm.SanModAct

31009

2

U32

FIX0

RO

-

-

-

-

-

-

-

%

-

-

-

-

Lower discharge limit for private consumption range

-

BatUsDm.SelfCsmpDmLim

31057

2

U32

TAGLIST

RO

-

-

-

-

-

-

-

-

2614: Own consumption area (SelfCsmpDm)

2615: State of charge conservation area (ChaSttDm)

2616: Backup power area (BckDm)

2617: Deep discharge protection area (DschProDm)

2618: Deep discharge area (ExhDschDm)

16777213: Information not available (NaNStt)

-

-

-

Status battery application area

-

BatUsDm.Stt

40733

2

U32

FIX2

RW Warnung vor zyklischem Beschreiben

-

-

-

-

-

-

-

V

41 V to 63 V

-

-

-

Voltage setpoint with deactivated battery mgmt

-

Cha.BMSInaVol

40039

2

U32

Dauer

RW Warnung vor zyklischem Beschreiben

-

-

-

-

-

-

-

min

1 min to 600 min

-

-

-

Battery boost charge time

-

Cha.BstChaTmm

40085

2

U32

FIX2

RW Warnung vor zyklischem Beschreiben

-

-

-

-

-

-

-

V

2.200000 V to 2.700000 V

-

-

-

Cell charge nominal voltage for boost charge

-

Cha.BstChaVolSpt

40083

2

U32

FIX3

RW Warnung vor zyklischem Beschreiben

-

-

-

-

-

-

-

A

0 A to 900 A

-

-

-

Maximum battery discharge current

-

Cha.DschAmpMax

40079

2

U32

FIX2

RW Warnung vor zyklischem Beschreiben

-

-

-

-

-

-

-

V

35 V to 63 V

-

-

-

Battery discharge cut-off voltage

-

Cha.DschStopVol

40741

2

U32

TAGLIST

RW Warnung vor zyklischem Beschreiben

-

-

-

-

-

-

-

-

303: Off (Off)

308: On (On)

-

-

-

Automatic equalization charge

-

Cha.EqChaAuto

31067

2

U32

FIX0

RO

-

-

-

-

-

-

-

kWh

-

-

-

-

Number of battery equalization charges

-

Cha.EqChaCnt

40737

2

U32

Dauer

RW Warnung vor zyklischem Beschreiben

-

-

-

-

-

-

-

s

604800 s to 31536000 s

-

-

-

Cycle time equalization charge

-

Cha.EqChaCycTm

40089

2

U32

FIX2

RW Warnung vor zyklischem Beschreiben

-

-

-

-

-

-

-

V

2.300000 V to 2.7 V

-

-

-

Cell charge nominal voltage for equalization charge

-

Cha.EqChaVolSpt

31073

2

U32

FIX0

RO

-

-

-

-

-

-

-

%

-

-

-

-

Relative battery discharge since last equalization charge

-

Cha.EqDschNom

40041

2

U32

Dauer

RW Warnung vor zyklischem Beschreiben

-

-

-

-

-

-

-

h

1 h to 48 h

-

-

-

Battery equalization charge time

-

Cha.EqChaTmh

31069

2

U32

FIX0

RO

-

-

-

-

-

-

-

s

-

-

-

-

Number of battery full charges

-

Cha.FulChaCnt

40735

2

U32

Dauer

RW Warnung vor zyklischem Beschreiben

-

-

-

-

-

-

-

s

86400 s to 15552000 s

-

-

-

Cycle time full charge

-

Cha.FulChaCycTm

40087

2

U32

FIX2

RW Warnung vor zyklischem Beschreiben

-

-

-

-

-

-

-

V

2.3 V to 2.7 V

-

-

-

Cell charge nominal voltage for full charging

-

Cha.FulChaVolSpt

40043

2

U32

Dauer

RW Warnung vor zyklischem Beschreiben

-

-

-

-

-

-

-

h

1 h to 20 h

-

-

-

Battery full charge time

-

Cha.FulChaTmh

31071

2

U32

FIX0

RO

-

-

-

-

-

-

-

%

-

-

-

-

Relative battery discharge since last full charge

-

Cha.FulDschNom

40045

2

U32

FIX3

RW Warnung vor zyklischem Beschreiben

-

-

-

-

-

-

-

A

10 A to 900 A

-

-

-

Max. battery charging current

-

Cha.MaxChaAmp

40739

2

S32

FIX3

RW Warnung vor zyklischem Beschreiben

-

-

-

-

-

-

-

V/°C

0 V/°C to 0.01 V/°C

-

-

-

Battery temperature compensation

-

Cha.TmpCpn

40091

2

U32

FIX2

RW Warnung vor zyklischem Beschreiben

-

-

-

-

-

-

-

V

2.2 V to 2.4 V

-

-

-

Cell charge nominal voltage for float charge

-

Cha.TrcChaVolSpt

40795

2

U32

FIX0

WO

-

-

-

-

-

-

-

W

-

-

-

Anlagensteuerobjekt

Max. battery charge capac.

-

CmpBMS.BatChaMaxW

40799

2

U32

FIX0

WO

-

-

-

-

-

-

-

W

-

-

-

Anlagensteuerobjekt

Max. battery discharge capac.

-

CmpBMS.BatDschMaxW

40801

2

S32

FIX0

WO

-

-

-

-

-

-

-

W

-

-

-

Anlagensteuerobjekt

Mains exch. capac. target value

-

CmpBMS.GridWSpt

40236

2

U32

TAGLIST

WO

-

-

-

-

-

-

-

-

303: Off (Off)

308: On (On)

2289: Charge battery (BatChaMod)

2290: Discharge battery (BatDschMod)

2424: Presetting (Dft)

-

-

Anlagensteuerobjekt

BMS operating mode

-

CmpBMS.OpMod

41259

2

U32

TAGLIST

RW

40375

StorCtl_Mod

124

1

uint16

-

RW

-

303: Off (Off)

308: On (On)

2289: Charge battery (BatChaMod)

2290: Discharge battery (BatDschMod)

2424: Presetting (Dft)

-

-

Anlagensteuerobjekt

BMS operating mode

-

CmpBMS.OpMod

40013

2

U32

TAGLIST

RW Warnung vor zyklischem Beschreiben

-

-

-

-

-

-

-

-

777: Deutsch (LangDE)

778: English (LangEN)

779: Italiano (LangIT)

780: Español (LangES)

781: Français (LangFR)

782: Ελληνικά (LangEL)

783: 한국어 (LangKO)

784: Česky (LangCS)

785: Português (LangPT)

786: Nederlands (LangNL)

798: Polski (LangPL)

801: ภาษาไทย (LangTH)

2

-

-

Language of the user interface

CntrySet.Lang

CntrySettings.Lang

34657

2

U32

TAGLIST

RO

-

-

-

-

-

-

-

-

-

-

-

-

Status digital input

-

DigIn.OpMod

40749

2

U32

TAGLIST

RO

-

-

-

-

-

-

-

-

-

-

-

-

Status digital input

-

DigIn.OpMod

40003

2

U32

TAGLIST

RW Warnung vor zyklischem Beschreiben

-

-

-

-

-

-

-

-

9499: (UTC-AUTO) Automatic via SMA protocol (TmZnTmSvr)

1

-

-

Time zone

-

DtTm.TmZn

40005

2

U32

TAGLIST

RW Warnung vor zyklischem Beschreiben

-

-

-

-

-

-

-

-

1129: Yes (Yes)

1130: No (No)

1

-

-

Standard/Daylight saving time conversion on

-

DtTm.DlSvIsOn

40669

2

U32

TM

RW Warnung vor zyklischem Beschreiben

-

-

-

-

-

-

-

-

0  to 86399 

-

-

-

Start feed-in PV

-

ExtGri.StrPvFeedTm

40671

2

U32

TM

RW Warnung vor zyklischem Beschreiben

-

-

-

-

-

-

-

-

0  to 86399 

-

-

-

Stop feed-in PV

-

ExtGri.StopPvFeedTm

30909

2

S32

FIX3

RO

-

-

-

-

-

-

-

A

-

-

-

-

Electricity external power connection phase A

-

ExtGridMs.A.phsA

30911

2

S32

FIX3

RO

-

-

-

-

-

-

-

A

-

-

-

-

Electricity external power connection phase B

-

ExtGridMs.A.phsB

30913

2

S32

FIX3

RO

-

-

-

-

-

-

-

A

-

-

-

-

Electricity external power connection phase C

-

ExtGridMs.A.phsC

30901

2

U32

FIX2

RO

-

-

-

-

-

-

-

Hz

-

-

-

-

Grid frequency of external power connection

-

ExtGridMs.Hz

30903

2

U32

FIX2

RO

-

-

-

-

-

-

-

V

-

-

-

-

Voltage external power connection phase A

-

ExtGridMs.PhV.phsA

30905

2

U32

FIX2

RO

-

-

-

-

-

-

-

V

-

-

-

-

Voltage external power connection phase B

-

ExtGridMs.PhV.phsB

30907

2

U32

FIX2

RO

-

-

-

-

-

-

-

V

-

-

-

-

Voltage external power connection phase C

-

ExtGridMs.PhV.phsC

40673

2

U32

Dauer

RW Warnung vor zyklischem Beschreiben

-

-

-

-

-

-

-

s

0 s to 3600 s

-

-

-

Cut-off time until connection to external network

-

ExtGridMs.ProLokTm

30985

2

S32

FIX3

RO

-

-

-

-

-

-

-

A

-

-

-

-

Total current external network connection

-

ExtGridMs.TotA

31425

2

S32

FIX0

RO

-

-

-

-

-

-

-

VAr

-

-

-

-

Reactive power external power connection

-

ExtGridMs.TotVAr

31417

2

S32

FIX0

RO

-

-

-

-

-

-

-

W

-

-

-

-

Output external power connection

-

ExtGridMs.TotW

31427

2

S32

FIX0

RO

-

-

-

-

-

-

-

VAr

-

-

-

-

Reactive power external power connection phase A

-

ExtGridMs.VAr.phsA

31429

2

S32

FIX0

RO

-

-

-

-

-

-

-

VAr

-

-

-

-

Reactive power external power connection phase B

-

ExtGridMs.VAr.phsB

31431

2

S32

FIX0

RO

-

-

-

-

-

-

-

VAr

-

-

-

-

Reactive power external power connection phase C

-

ExtGridMs.VAr.phsC

31419

2

S32

FIX0

RO

-

-

-

-

-

-

-

W

-

-

-

-

Output external power connection phase A

-

ExtGridMs.W.phsA

31421

2

S32

FIX0

RO

-

-

-

-

-

-

-

W

-

-

-

-

Output external power connection phase B

-

ExtGridMs.W.phsB

31423

2

S32

FIX0

RO

-

-

-

-

-

-

-

W

-

-

-

-

Output external power connection phase C

-

ExtGridMs.W.phsC

40047

2

U32

FIX3

RW Warnung vor zyklischem Beschreiben

-

-

-

-

-

-

-

A

-

-

-

-

Rated generator current

-

Gn.ARtg

40049

2

U32

TAGLIST

RW Warnung vor zyklischem Beschreiben

-

-

-

-

-

-

-

-

303: Off (Off)

308: On (On)

-

-

-

Automatic generator start

-

Gn.AutoStr

30565

2

U32

FIX0

RO

-

-

-

-

-

-

-

-

-

-

-

-

Number of generator starts

-

Gn.Diag.StrCnt

40055

2

U32

TAGLIST

RW Warnung vor zyklischem Beschreiben

-

-

-

-

-

-

-

-

381: Stop (Stop)

1467: Start (Str)

1776: Manual one hour (Man1h)

10908: Automatic generator start (Gn.AutoStr)

-

-

-

Manual generator control

-

Gn.ManCtl

40137

2

U32

TAGLIST

RW Warnung vor zyklischem Beschreiben

-

-

-

-

-

-

-

-

26: Acknowledge fault (Ackn)

-

-

-

Acknowledge generator errors

-

Gn.Operation.Ackn

30917

2

U32

TAGLIST

RO

-

-

-

-

-

-

-

-

303: Off (Off)

1392: Fault (Flt)

1787: Initialization (Init)

1788: Ready (Rdy)

1789: Warming (Warming)

1790: Synchronization (Syn)

1791: Activated (ConnAct)

1792: Resynchronization (ReSyn)

1793: Generator separation (GnDscon)

1794: Slow down (StopDl)

1795: Bolted (Lok)

1796: Blocked after error (FltLok)

16777213: Information not available (NaNStt)

-

-

-

Generator status

-

Gn.OpStt

40111

2

U32

FIX2

RW Warnung vor zyklischem Beschreiben

-

-

-

-

-

-

-

V

-

-

-

-

Voltage monit. gener. lower minimum threshold

-

Gn.VolCtl.Min

40113

2

U32

FIX2

RW Warnung vor zyklischem Beschreiben

-

-

-

-

-

-

-

V

-

-

-

-

Voltage monit. gener. upper maximum threshold

-

Gn.VolCtl.Max

40115

2

U32

FIX2

RW Warnung vor zyklischem Beschreiben

-

-

-

-

-

-

-

V

0 V to 10 V

-

-

-

Voltage monit. gener. hysteresis min. threshold

-

Gn.VolCtl.ReconMinDif

40117

2

U32

FIX2

RW Warnung vor zyklischem Beschreiben

-

-

-

-

-

-

-

V

0 V to 10 V

-

-

-

Voltage monit. hysteresis generator max. threshold

-

Gn.VolCtl.ReconMaxDif

40119

2

U32

FIX2

RW Warnung vor zyklischem Beschreiben

-

-

-

-

-

-

-

Hz

-

-

-

-

Frequency monit. generator lower minimum threshold

-

Gn.FrqCtl.Min

40121

2

U32

FIX2

RW Warnung vor zyklischem Beschreiben

-

-

-

-

-

-

-

Hz

-

-

-

-

Frequency monit. generator without max. threshold

-

Gn.FrqCtl.Max

40123

2

U32

FIX2

RW Warnung vor zyklischem Beschreiben

-

-

-

-

-

-

-

Hz

0 Hz to 2 Hz

-

-

-

Frequency monit. gener. hysteresis min. threshold

-

Gn.FrqCtl.ReconMinDif

40125

2

U32

FIX2

RW Warnung vor zyklischem Beschreiben

-

-

-

-

-

-

-

Hz

0 Hz to 2 Hz

-

-

-

Freq. Monit. generator hysteresis max. threshold

-

Gn.FrqCtl.ReconMaxDif

40127

2

U32

FIX0

RW Warnung vor zyklischem Beschreiben

-

-

-

-

-

-

-

W

-

-

-

-

Voltage monitoring generator maximum reverse power

-

Gn.WMon.RvPwrMax

40129

2

U32

Dauer

RW Warnung vor zyklischem Beschreiben

-

-

-

-

-

-

-

s

0 s to 900 s

-

-

-

Volt. monit. gener. max. reverse power trip. time

-

Gn.WMon.RvPwrMaxTms

40535

2

U32

TAGLIST

RW Warnung vor zyklischem Beschreiben

-

-

-

-

-

-

-

-

10908: Automatic generator start (Gn.AutoStr)

10911: Manual generator control (Gn.ManCtl)

-

-

-

Generator request

-

Gn.DmdMod

40537

2

U32

FIX0

RW Warnung vor zyklischem Beschreiben

-

-

-

-

-

-

-

%

-

-

-

-

Limit battery state of charge generator start in time range

-

GnDmdBatCha.OnLim

40539

2

U32

FIX0

RW Warnung vor zyklischem Beschreiben

-

-

-

-

-

-

-

%

-

-

-

-

Limit battery state of charge gen. shutdown in time range

-

GnDmdBatCha.OffLim

40541

2

U32

TM

RW Warnung vor zyklischem Beschreiben

-

-

-

-

-

-

-

-

0  to 86399 

-

-

-

Start time additional time range generator request

-

GnDmdBatCha.AddTm.StrTm

40543

2

U32

TM

RW Warnung vor zyklischem Beschreiben

-

-

-

-

-

-

-

-

0  to 86399 

-

-

-

Start time range for generator request

-

GnDmdBatCha.AddTm.StopTm

40545

2

U32

FIX0

RW Warnung vor zyklischem Beschreiben

-

-

-

-

-

-

-

%

-

-

-

-

Limit battery state of charge generator stop in add time range

-

GnDmdBatCha.AddTm.OnLim

40547

2

U32

FIX0

RW Warnung vor zyklischem Beschreiben

-

-

-

-

-

-

-

%

-

-

-

-

Limit battery state of charge generator start in add time range

-

GnDmdBatCha.AddTm.OffLim

40557

2

U32

TAGLIST

RW Warnung vor zyklischem Beschreiben

-

-

-

-

-

-

-

-

303: Off (Off)

1736: Full and equalization charge (FulEqCha)

1768: Full charge (FulCha)

1769: Equalization charge (EqCha)

-

-

-

Generator request with set charge type

-

GnDmdChaMod.ChaMod

40559

2

U32

TAGLIST

RW Warnung vor zyklischem Beschreiben

-

-

-

-

-

-

-

-

303: Off (Off)

308: On (On)

-

-

-

Reaction to digital input of generator request

-

GnDmdDigIn.DigInRea

40549

2

U32

TAGLIST

RW Warnung vor zyklischem Beschreiben

-

-

-

-

-

-

-

-

1129: Yes (Yes)

1130: No (No)

-

-

-

Time-controlled generator operation

-

GnDmdTm.IsOn

40551

2

U32

DT

RW Warnung vor zyklischem Beschreiben

-

-

-

-

-

-

-

-

1293840000  to 4102444799 

-

-

-

Start time for time-controlled generator op.

-

GnDmdTm.StrTm

40553

2

U32

Dauer

RW Warnung vor zyklischem Beschreiben

-

-

-

-

-

-

-

s

0 s to 359940 s

-

-

-

Operating time for time-controlled generator op.

-

GnDmdTm.RunTm

40555

2

U32

TAGLIST

RW Warnung vor zyklischem Beschreiben

-

-

-

-

-

-

-

-

1189: daily (IntvDy)

2622: Once (IntvOc)

2623: Weekly (IntvWk)

-

-

-

Repeat cycle of time-controlled generator op.

-

GnDmdTm.RptCyc

40057

2

U32

TAGLIST

RW Warnung vor zyklischem Beschreiben

-

-

-

-

-

-

-

-

1129: Yes (Yes)

1130: No (No)

-

-

-

Generator request via power on

-

GnDmdW.IsOn

40561

2

U32

Dauer

RW Warnung vor zyklischem Beschreiben

-

-

-

-

-

-

-

s

1 s to 900 s

-

-

-

Average time for generator request via power

-

GnDmdW.WAvTm

40059

2

U32

FIX0

RW Warnung vor zyklischem Beschreiben

-

-

-

-

-

-

-

W

-

-

-

-

Generator shutdown load limit

-

GnDmdW.WOff

40061

2

U32

FIX0

RW Warnung vor zyklischem Beschreiben

-

-

-

-

-

-

-

W

-

-

-

-

Generator startup load limit

-

GnDmdW.WOn

40109

2

U32

TAGLIST

RO

-

-

-

-

-

-

-

-

27: Special setting (Adj)

305: Island mode (OFF-Grid)

7510: DE VDE-AR-N4105 (VDE-AR-N4105)

7517: IT CEI 0-21 intern (CEI0-21Int)

7523: BE C10/11/2012 (C10/11/2012)

7527: FR VFR2014 (VFR2014)

7542: DE GPPWide (GPPWide)

7543: CH VDE_0126-1-1-CH (VDE0126-1-1_CH)

7544: DK VDE-AR-N4105-DK (VDE-AR-N4105-DK)

7545: DE VDE-AR-N4105-MC (VDE-AR-N4105-MC)

7546: SMA Adjusted-MC (Adjusted-MC)

7547: AT OENORME80014712 (OENORME80014712)

7549: AU AS4777.2_2015 (AS4777.2_2015)

16777213: Information not available (NaNStt)

-

-

-

Country standard set

Cntry

GridGuard.Cntry

41121

2

U32

FUNKTION_SEC

RW Warnung vor zyklischem Beschreiben

-

-

-

-

-

-

-

-

-

SMA Guard Code

-

Set country standard

CntrySet

GridGuard.CntrySet

40101

2

U32

FIX2

RW Warnung vor zyklischem Beschreiben

-

-

-

-

-

-

-

Hz

-

-

SMA Guard Code

-

Frequency monitoring, lower minimum threshold

FrqCtl.Min

GridGuard.Cntry.FrqCtl.Min

40103

2

U32

FIX2

RW Warnung vor zyklischem Beschreiben

-

-

-

-

-

-

-

Hz

-

-

SMA Guard Code

-

Frequency monitoring upper maximum threshold

FrqCtl.Max

GridGuard.Cntry.FrqCtl.Max

40105

2

U32

FIX2

RW Warnung vor zyklischem Beschreiben

-

-

-

-

-

-

-

Hz

0 Hz to 2.500000 Hz

-

SMA Guard Code

-

Frequency monitoring hysteresis minimum threshold

-

GridGuard.Cntry.FrqCtl.ReconMinDif

40107

2

U32

FIX2

RW Warnung vor zyklischem Beschreiben

-

-

-

-

-

-

-

Hz

0 Hz to 2.500000 Hz

-

SMA Guard Code

-

Frequency monitoring hysteresis maximum threshold

-

GridGuard.Cntry.FrqCtl.ReconMaxDif

40135

2

U32

FIX2

RW Warnung vor zyklischem Beschreiben

40286

ECPNomHz

121

1

uint16

40297

RW Warnung vor zyklischem Beschreiben

Hz

-

-

SMA Guard Code

-

Nominal frequency

HzRtg

GridGuard.Cntry.HzRtg

40093

2

U32

FIX2

RW Warnung vor zyklischem Beschreiben

-

-

-

-

-

-

-

V

-

-

SMA Guard Code

-

Voltage monitoring lower minimum threshold

-

GridGuard.Cntry.VolCtl.Min

40095

2

U32

FIX2

RW Warnung vor zyklischem Beschreiben

-

-

-

-

-

-

-

V

-

-

SMA Guard Code

-

Voltage monitoring upper maximum threshold

VolCtl.Max

GridGuard.Cntry.VolCtl.Max

40097

2

U32

FIX2

RW Warnung vor zyklischem Beschreiben

-

-

-

-

-

-

-

V

0 V to 20 V

-

SMA Guard Code

-

Voltage monitoring hysteresis minimum threshold

-

GridGuard.Cntry.VolCtl.ReconMinDif

40099

2

U32

FIX2

RW Warnung vor zyklischem Beschreiben

-

-

-

-

-

-

-

V

0 V to 12 V

-

SMA Guard Code

-

Voltage monitoring hysteresis maximum threshold

-

GridGuard.Cntry.VolCtl.ReconMaxDif

41295

2

U32

TAGLIST

RW Warnung vor zyklischem Beschreiben

-

-

-

-

-

-

-

-

3658: Symmetric (Sym)

3659: Asymmetric (Asym)

1

-

-

Design of the generation plant

-

GridGuard.EzaTyp

30783

2

U32

FIX2

RO

40196

PhVphA

101

1

uint16

40199

RO

V

-

-

-

-

Grid voltage phase L1

GridMs.PhV.phsA

GridMs.PhV.phsA

30785

2

U32

FIX2

RO

40197

PhVphB

101

1

uint16

40199

RO

V

-

-

-

-

Grid voltage phase L2

GridMs.PhV.phsB

GridMs.PhV.phsB

30787

2

U32

FIX2

RO

40198

PhVphC

101

1

uint16

40199

RO

V

-

-

-

-

Grid voltage phase L3

GridMs.PhV.phsC

GridMs.PhV.phsC

30977

2

S32

FIX3

RO

40189

AphA

101

1

int16

40192

RO

A

-

-

-

-

Grid current phase L1

GridMs.A.phsA

GridMs.A.phsA

30979

2

S32

FIX3

RO

40190

AphB

101

1

int16

40192

RO

A

-

-

-

-

Grid current phase L2

GridMs.A.phsB

GridMs.A.phsB

30981

2

S32

FIX3

RO

40191

AphC

101

1

int16

40192

RO

A

-

-

-

-

Grid current phase L3

GridMs.A.phsC

GridMs.A.phsC

30803

2

U32

FIX2

RO

40202

Hz

101

1

uint16

40203

RO

Hz

-

-

-

-

Grid frequency

GridMs.Hz

GridMs.Hz

30805

2

S32

FIX0

RO

40206

VAr

101

1

int16

40207

RO

VAr

-

-

-

-

Reactive power

GridMs.TotVAr

GridMs.TotVAr

30775

2

S32

FIX0

RO

40200

W

101

1

int16

40201

RO

W

-

-

-

-

Power

Pac

GridMs.TotW

30807

2

S32

FIX0

RO

-

-

-

-

-

-

-

VAr

-

-

-

-

Reactive power L1

GridMs.VAr.phsA

GridMs.VAr.phsA

30809

2

S32

FIX0

RO

-

-

-

-

-

-

-

VAr

-

-

-

-

Reactive power L2

GridMs.VAr.phsB

GridMs.VAr.phsB

30811

2

S32

FIX0

RO

-

-

-

-

-

-

-

VAr

-

-

-

-

Reactive power L3

GridMs.VAr.phsC

GridMs.VAr.phsC

30777

2

S32

FIX0

RO

-

-

-

-

-

-

-

W

-

-

-

-

Power L1

GridMs.W.phsA

GridMs.W.phsA

30779

2

S32

FIX0

RO

-

-

-

-

-

-

-

W

-

-

-

-

Power L2

GridMs.W.phsB

GridMs.W.phsB

30781

2

S32

FIX0

RO

-

-

-

-

-

-

-

W

-

-

-

-

Power L3

GridMs.W.phsC

GridMs.W.phsC

40755

2

U32

FIX3

RW Warnung vor zyklischem Beschreiben

-

-

-

-

-

-

-

A

-

-

-

-

Maximum AC battery charge current

-

Inverter.AcChaAMax

41283

2

U32

TAGLIST

RW Warnung vor zyklischem Beschreiben

-

-

-

-

-

-

-

-

3647: 230V_50Hz (230V_50Hz)

3648: 220V_60Hz (220V_60Hz)

-

-

-

Nominal voltage and frequency

-

Inverter.AcVHzTyp

41291

2

U32

FIX0

RW Warnung vor zyklischem Beschreiben

-

-

-

-

-

-

-

-

1  to 11 

-

-

-

Extension cluster address

-

Inverter.Clt.Addr

41289

2

U32

TAGLIST

RW Warnung vor zyklischem Beschreiben

-

-

-

-

-

-

-

-

302: ------- (None)

3653: Main-cluster (MainClt)

3654: Extension cluster (ExtnClt)

-

-

-

Cluster in the multi-cluster

-

Inverter.Clt.CltMod

41287

2

U32

TAGLIST

RW Warnung vor zyklischem Beschreiben

-

-

-

-

-

-

-

-

3652: Single-cluster (SingleClt)

3663: Multi-cluster (MltClt)

-

-

-

Cluster system

-

Inverter.Clt.Sys

41285

2

U32

TAGLIST

RW Warnung vor zyklischem Beschreiben

-

-

-

-

-

-

-

-

3649: Single phase (1Phs)

3650: Three-phase (3Phs)

-

-

-

Cluster configuration

-

Inverter.Clt.Typ

41187

2

U32

TAGLIST

RW Warnung vor zyklischem Beschreiben

-

-

-

-

-

-

-

-

3547: Inverter (MsSrcDev)

3548: MC box (MsSrcMltBox)

-

-

-

Source of ref. meas. for reactive/active power reduction

-

Inverter.CtlComCfg.CtlMsSrc

41189

2

U32

TAGLIST

RW Warnung vor zyklischem Beschreiben

-

-

-

-

-

-

-

-

303: Off (Off)

308: On (On)

-

-

-

Phased reactive/act. power specification

-

Inverter.CtlComCfg.PhsCtlMod

41191

2

U32

TAGLIST

RW Warnung vor zyklischem Beschreiben

-

-

-

-

-

-

-

-

3550: Functions for grid operation (OnGriMod)

3551: Functions for offgrid operation (OffGriMod)

-

-

-

Functions for grid/offgrid operation

-

Inverter.GriOffOpMod

40753

2

U32

FIX0

RW Warnung vor zyklischem Beschreiben

-

-

-

-

-

-

-

Hz

-

-

-

-

Inverter nominal frequency

-

Inverter.HzRtg

40183

2

U32

TAGLIST

RW Warnung vor zyklischem Beschreiben

40287

ConnPh

121

1

uint16

-

RW Warnung vor zyklischem Beschreiben

-

325: Phase L1 (phsA)

327: Phase L2 (phsB)

329: Phase L3 (phsC)

-

-

-

Phase assignment

Inv.OutPhsSet

Inverter.OutPhs

41293

2

U32

TAGLIST

RW Warnung vor zyklischem Beschreiben

-

-

-

-

-

-

-

-

3655: Self-consumption only (SelfConsOnly)

3656: Backup only (BackupOnly)

3657: Self-consumption and backup (SelfConsBackup)

-

-

-

System performance

-

Inverter.SysFncSel

30831

2

S32

FIX2

RO

-

-

-

-

-

-

-

-

0.8  to 1.0 

-

SMA Guard Code

-

cosPhi setpoint, cosPhi config., direct specif.

PF-PF

Inverter.VArModCfg.PFCnstCfg.PF

40206

2

S32

FIX2

RW Warnung vor zyklischem Beschreiben

-

-

-

-

-

-

-

-

0.8  to 1.0 

-

SMA Guard Code

-

cosPhi setpoint, cosPhi config., direct specif.

PF-PF

Inverter.VArModCfg.PFCnstCfg.PF

30833

2

U32

TAGLIST

RO

-

-

-

-

-

-

-

-

1041: Overexcited (OvExt)

1042: Underexcited (UnExt)

-

SMA Guard Code

-

cosPhi excit.type, cosPhi config., direct spec.

PF-PFExt

Inverter.VArModCfg.PFCnstCfg.PFExt

40208

2

U32

TAGLIST

RW Warnung vor zyklischem Beschreiben

-

-

-

-

-

-

-

-

1041: Overexcited (OvExt)

1042: Underexcited (UnExt)

-

SMA Guard Code

-

cosPhi excit.type, cosPhi config., direct spec.

PF-PFExt

Inverter.VArModCfg.PFCnstCfg.PFExt

40222

2

U32

FIX2

RW Warnung vor zyklischem Beschreiben

-

-

-

-

-

-

-

-

0.8  to 1.0 

-

SMA Guard Code

-

cosPhi at start point, cosPhi(P) char. config.

PF-PFStr

Inverter.VArModCfg.PFCtlWCfg.PFStr

40224

2

U32

TAGLIST

RW Warnung vor zyklischem Beschreiben

-

-

-

-

-

-

-

-

1041: Overexcited (OvExt)

1042: Underexcited (UnExt)

-

SMA Guard Code

-

Excit. type at start point, cosPhi(P) char. conf.

PF-PFExtStr

Inverter.VArModCfg.PFCtlWCfg.PFExtStr

40226

2

U32

FIX2

RW Warnung vor zyklischem Beschreiben

-

-

-

-

-

-

-

-

0.8  to 1.0 

-

SMA Guard Code

-

cosPhi at end point, cosPhi(P) char. config.

PF-PFStop

Inverter.VArModCfg.PFCtlWCfg.PFStop

40228

2

U32

TAGLIST

RW Warnung vor zyklischem Beschreiben

-

-

-

-

-

-

-

-

1041: Overexcited (OvExt)

1042: Underexcited (UnExt)

-

SMA Guard Code

-

Excit. type at end point, cosPhi(P) char. config.

PF-PFExtStop

Inverter.VArModCfg.PFCtlWCfg.PFExtStop

40232

2

U32

FIX0

RW Warnung vor zyklischem Beschreiben

-

-

-

-

-

-

-

%

-

-

SMA Guard Code

-

Act. power at end point, cosPhi(P) char. config.

PF-WNomStop

Inverter.VArModCfg.PFCtlWCfg.WNomStop

40230

2

U32

FIX0

RW Warnung vor zyklischem Beschreiben

-

-

-

-

-

-

-

%

-

-

SMA Guard Code

-

Act. power at start point, cosPhi(P) char. config.

PF-WNomStr

Inverter.VArModCfg.PFCtlWCfg.WNomStr

40153

2

S32

FIX0

WO

-

-

-

-

-

-

-

VAr

-

-

-

Anlagensteuerobjekt

Reactive power setpoint

-

Inverter.VArModCfg.VArCtlComCfg.VArSpt

40833

2

S32

FIX0

WO

-

-

-

-

-

-

-

VAr

-

-

-

Anlagensteuerobjekt

Reactive power setpoint

-

Inverter.VArModCfg.VArCtlComCfg.VArSpt

41181

2

S32

FIX0

WO

-

-

-

-

-

-

-

VAr

-

-

-

Anlagensteuerobjekt

-

-

Inverter.VArModCfg.VArCtlComCfg.VArSpt.phsA

41183

2

S32

FIX0

WO

-

-

-

-

-

-

-

VAr

-

-

-

Anlagensteuerobjekt

-

-

Inverter.VArModCfg.VArCtlComCfg.VArSpt.phsB

41185

2

S32

FIX0

WO

-

-

-

-

-

-

-

VAr

-

-

-

Anlagensteuerobjekt

-

-

Inverter.VArModCfg.VArCtlComCfg.VArSpt.phsC

30825

2

U32

TAGLIST

RO

-

-

-

-

-

-

-

-

303: Off (Off)

1074: Cos Phi, manual setting (PFCnst)

1076: Cos Phi(P) charac. curve (PFCtlW)

-

SMA Guard Code

-

Operating mode of stat.V stab., stat.V stab. config.

Q-VArMod

Inverter.VArModCfg.VArMod

40200

2

U32

TAGLIST

RW Warnung vor zyklischem Beschreiben

40366
40358

VArPct_Ena
OutPFSet_Ena

123
123

1
1

uint16
uint16

-

RW Warnung vor zyklischem Beschreiben
RW Warnung vor zyklischem Beschreiben

-

303: Off (Off)

1074: Cos Phi, manual setting (PFCnst)

1076: Cos Phi(P) charac. curve (PFCtlW)

-

SMA Guard Code

-

Operating mode of stat.V stab., stat.V stab. config.

Q-VArMod

Inverter.VArModCfg.VArMod

40751

2

U32

FIX0

RW Warnung vor zyklischem Beschreiben

-

-

-

-

-

-

-

V

-

-

-

-

Inverter nominal voltage

InvVtgNom

Inverter.VRtg

40218

2

U32

FIX2

RW Warnung vor zyklischem Beschreiben

40465

HzStr

127

1

int16

40471

RW Warnung vor zyklischem Beschreiben

Hz

0 Hz to 5 Hz

-

SMA Guard Code

-

Difference between starting frequency and grid frequency, linear instantaneous power gradient configuration

P-HzStr

Inverter.WCtlHzModCfg.WCtlHzCfg.HzStr

40220

2

U32

FIX2

RW Warnung vor zyklischem Beschreiben

40466

HzStop

127

1

int16

40471

RW Warnung vor zyklischem Beschreiben

Hz

0 Hz to 5 Hz

-

SMA Guard Code

-

Difference between reset frequency and grid frequency, linear instantaneous power gradient configuration

P-HzStop

Inverter.WCtlHzModCfg.WCtlHzCfg.HzStop

40238

2

U32

FIX0

RW Warnung vor zyklischem Beschreiben

40464

WGra

127

1

uint16

40470

RW Warnung vor zyklischem Beschreiben

%

10 % to 130 %

-

SMA Guard Code

-

Active power gradient, linear instantaneous power gradient configuration

P-WGra

Inverter.WCtlHzModCfg.WCtlHzCfg.WGra

40216

2

U32

TAGLIST

RW Warnung vor zyklischem Beschreiben

40468

ModEna

127

1

uint16

-

RW Warnung vor zyklischem Beschreiben

-

303: Off (Off)

1132: Frequency-dependent active power adapt. P(f) (WCtlHz)

-

SMA Guard Code

-

Operating mode of active power reduction in case of overfrequency P(f)

P-WCtlHzMod

Inverter.WCtlHzModCfg.WCtlHzMod

30231

2

U32

FIX0

RO

40241

WRtg

120

1

uint16

40242

RO

W

0 W to 20000 W

-

-

-

Maximum active power device

Plimit

Inverter.WLim

41175

2

S32

FIX0

WO

-

-

-

-

-

-

-

W

-

-

-

Anlagensteuerobjekt

-

-

Inverter.WModCfg.WCtlComCfg.W.phsA

41177

2

S32

FIX0

WO

-

-

-

-

-

-

-

W

-

-

-

Anlagensteuerobjekt

-

-

Inverter.WModCfg.WCtlComCfg.W.phsB

41179

2

S32

FIX0

WO

-

-

-

-

-

-

-

W

-

-

-

Anlagensteuerobjekt

-

-

Inverter.WModCfg.WCtlComCfg.W.phsC

40151

2

U32

TAGLIST

WO

-

-

-

-

-

-

-

-

802: Active (Act)

803: Inactive (Ina)

-

-

Anlagensteuerobjekt

Eff./reac. pow. contr. via comm.

FedInSpntCom

Inverter.WModCfg.WCtlComCfg.WCtlComAct

40149

2

S32

FIX0

WO

-

-

-

-

-

-

-

W

-

-

-

Anlagensteuerobjekt

Active power setpoint

FedInPwrAtCom

Inverter.WModCfg.WCtlComCfg.WSpt

30835

2

U32

TAGLIST

RO

-

-

-

-

-

-

-

-

1079: External setting (WCtlCom)

-

SMA Guard Code

-

Operating mode active power setting

P-WMod

Inverter.WModCfg.WMod

40210

2

U32

TAGLIST

RW Warnung vor zyklischem Beschreiben

40353

WMaxLim_Ena

123

1

uint16

-

RW Warnung vor zyklischem Beschreiben

-

1079: External setting (WCtlCom)

-

SMA Guard Code

-

Operating mode active power setting

P-WMod

Inverter.WModCfg.WMod

40757

2

U32

FIX0

RW Warnung vor zyklischem Beschreiben

-

-

-

-

-

-

-

%

-

-

-

-

Lmt value battery state of charge for start load shedding 1

-

LodShd1.ChaStrLim

40759

2

U32

FIX0

RW Warnung vor zyklischem Beschreiben

-

-

-

-

-

-

-

%

-

-

-

-

Lmt value battery state of charge for stop load shedding 1

-

LodShd1.ChaStopLim

40761

2

U32

TM

RW Warnung vor zyklischem Beschreiben

-

-

-

-

-

-

-

-

0  to 86399 

-

-

-

Start time additional time range load shedding 1

-

LodShd1.AddTm.StrTm

40763

2

U32

TM

RW Warnung vor zyklischem Beschreiben

-

-

-

-

-

-

-

-

0  to 86399 

-

-

-

Time load shedding 1

-

LodShd1.AddTm.StopTm

40765

2

U32

FIX0

RW Warnung vor zyklischem Beschreiben

-

-

-

-

-

-

-

%

-

-

-

-

Limit battery state of charge for start load shedding 1 in add time range

-

LodShd1.AddTm.ChaStrLim

40767

2

U32

FIX0

RW Warnung vor zyklischem Beschreiben

-

-

-

-

-

-

-

%

-

-

-

-

Limit battery state of charge for stop load shedding 1 in add time range

-

LodShd1.AddTm.ChaStopLim

40769

2

U32

FIX0

RW Warnung vor zyklischem Beschreiben

-

-

-

-

-

-

-

%

-

-

-

-

Lmt value battery state of charge for start load shedding 2

-

LodShd2.ChaStrLim

40771

2

U32

FIX0

RW Warnung vor zyklischem Beschreiben

-

-

-

-

-

-

-

%

-

-

-

-

Lmt value battery state of charge for stop load shedding 2

-

LodShd2.ChaStopLim

40773

2

U32

TM

RW Warnung vor zyklischem Beschreiben

-

-

-

-

-

-

-

-

0  to 86399 

-

-

-

Start time additional time range load shedding 2

-

LodShd2.AddTm.StrTm

40775

2

U32

TM

RW Warnung vor zyklischem Beschreiben

-

-

-

-

-

-

-

-

0  to 86399 

-

-

-

Time load shedding 2

-

LodShd2.AddTm.StopTm

40777

2

U32

FIX0

RW Warnung vor zyklischem Beschreiben

-

-

-

-

-

-

-

%

-

-

-

-

Limit battery state of charge for start load shedding 2 in add time range

-

LodShd2.AddTm.ChaStrLim

40779

2

U32

FIX0

RW Warnung vor zyklischem Beschreiben

-

-

-

-

-

-

-

%

-

-

-

-

Limit battery state of charge for stop load shedding 2 in add time range

-

LodShd2.AddTm.ChaStopLim

30859

2

U32

TAGLIST

RO

-

-

-

-

-

-

-

-

803: Inactive (Ina)

1771: Charge with solar power (PVCha)

1772: Charge w. solar a. mains power (GriPVCha)

16777213: Information not available (NaNStt)

-

-

-

Battery maint. state of charge

-

Maint.FulEqCha

30571

2

U32

FIX0

RO

-

-

-

-

-

-

-

Wh

-

-

-

-

Meter reading consumption meter

-

Metering.Csmp.TotWhIn

30861

2

S32

FIX0

RO

-

-

-

-

-

-

-

W

-

-

-

-

Load power

-

Metering.Csmp.TotWIn

31075

2

U32

Dauer

RO

-

-

-

-

-

-

-

s

-

-

-

-

Operating time energy count

-

Metering.EnCntTm

30585

2

U32

Dauer

RO

-

-

-

-

-

-

-

s

-

-

-

-

Power outage

-

Metering.GriFailTms

30577

2

U32

FIX0

RO

-

-

-

-

-

-

-

Wh

-

-

-

-

Energy drawn today

-

Metering.GridMs.DyWhIn

30579

2

U32

FIX0

RO

-

-

-

-

-

-

-

Wh

-

-

-

-

Energy fed into grid (today)

-

Metering.GridMs.DyWhOut

30867

2

S32

FIX0

RO

-

-

-

-

-

-

-

W

-

-

-

-

Power grid feed-in

-

Metering.GridMs.TotWOut

30865

2

S32

FIX0

RO

-

-

-

-

-

-

-

W

-

-

-

-

Power drawn

-

Metering.GridMs.TotWIn

30583

2

U32

FIX0

RO

-

-

-

-

-

-

-

Wh

-

-

-

-

Grid feed-in counter reading

GM.TotWhOut

Metering.GridMs.TotWhOut

30581

2

U32

FIX0

RO

-

-

-

-

-

-

-

Wh

-

-

-

-

Counter reading of power drawn counter

-

Metering.GridMs.TotWhIn

31011

2

U32

FIX3

RO

-

-

-

-

-

-

-

A

-

-

-

-

Total output current of solar charger

-

Metering.PvChaMs.Amp

31065

2

U32

FIX0

RO

-

-

-

-

-

-

-

Wh

-

-

-

-

Total energy of photovoltaics current day

-

Metering.PvChaMs.DyWhPv

31063

2

U32

FIX0

RO

-

-

-

-

-

-

-

kWh

-

-

-

-

Total energy of photovoltaics

-

Metering.PvChaMs.TotWhPv

31077

2

U32

FIX0

RO

-

-

-

-

-

-

-

Wh

-

-

-

-

Photovoltaic energy in solar charger

-

Metering.PvChaMs.TotWhSICha

31079

2

U32

FIX0

RO

-

-

-

-

-

-

-

Wh

-

-

-

-

Photovoltaic energy in solar charger

-

Metering.PvChaMs.TotWhSICha

31081

2

U32

FIX0

RO

-

-

-

-

-

-

-

Wh

-

-

-

-

Photovoltaic energy in solar charger

-

Metering.PvChaMs.TotWhSICha

31083

2

U32

FIX0

RO

-

-

-

-

-

-

-

Wh

-

-

-

-

Photovoltaic energy in solar charger

-

Metering.PvChaMs.TotWhSICha

30983

2

U32

FIX0

RO

-

-

-

-

-

-

-

W

-

-

-

-

Output of photovoltaics

-

Metering.PvChaMs.TotWPv

30869

2

S32

FIX0

RO

-

-

-

-

-

-

-

W

-

-

-

-

PV power generated

-

Metering.PvMs.TotWOut

30587

2

U32

FIX0

RO

-

-

-

-

-

-

-

Wh

-

-

-

-

PV generation counter reading

-

Metering.PvMs.TotWhOut

30589

2

U32

FIX0

RO

-

-

-

-

-

-

-

Wh

-

-

-

-

Total increased self-consumption

-

Metering.SelfCsmp.AbsSelfCsmpInc

30591

2

U32

FIX0

RO

-

-

-

-

-

-

-

Wh

-

-

-

-

Today's increased self-consumption

-

Metering.SelfCsmp.DySelfCsmpInc

30593

2

U32

FIX0

RO

-

-

-

-

-

-

-

Wh

-

-

-

-

Energy consumed internally

-

Metering.SelfCsmp.SelfCsmpWh

30873

2

S32

FIX0

RO

-

-

-

-

-

-

-

W

-

-

-

-

Current rise in self-consumption

-

Metering.SelfCsmp.SelfCsmpInc

30513

4

U64

FIX0

RO

40303
40210

ActWh
WH

122
101

4
2

acc64
acc32

-
40212

RO
RO

Wh

-

-

-

-

Total yield

E-Total

Metering.TotWhOut

30529

2

U32

FIX0

RO

-

-

-

-

-

-

-

Wh

-

-

-

-

Total yield

E-Total

Metering.TotWhOut

30531

2

U32

FIX0

RO

-

-

-

-

-

-

-

kWh

-

-

-

-

Total yield

E-Total

Metering.TotWhOut

30533

2

U32

FIX0

RO

-

-

-

-

-

-

-

MWh

-

-

-

-

Total yield

E-Total

Metering.TotWhOut

30595

2

U32

FIX0

RO

-

-

-

-

-

-

-

Wh

-

-

-

-

Absorbed energy

-

Metering.WhIn

30597

2

U32

FIX0

RO

-

-

-

-

-

-

-

Wh

-

-

-

-

Released energy

-

Metering.WhOut

40781

2

S32

TEMP

RW Warnung vor zyklischem Beschreiben

-

-

-

-

-

-

-

°C

-

-

-

-

Temp lmt for multifunct. relay with batt comp fan

-

MltFncSw.BatFanTmp

40619

2

U32

DT

RW Warnung vor zyklischem Beschreiben

-

-

-

-

-

-

-

-

1293840000  to 4102444799 

-

-

-

Start date of relay control for timer

-

MltFncSw.Tmr.TmCtlStr

40621

2

U32

DT

RW Warnung vor zyklischem Beschreiben

-

-

-

-

-

-

-

-

1293840000  to 4102444799 

-

-

-

Start date of relay control for timer

-

MltFncSw.Tmr.TmCtlStr

40615

2

U32

Dauer

RW Warnung vor zyklischem Beschreiben

-

-

-

-

-

-

-

s

0 s to 359940 s

-

-

-

Duration for which multifunction relay is activated for timer

-

MltFncSw.Tmr.TmCtlOn

40617

2

U32

Dauer

RW Warnung vor zyklischem Beschreiben

-

-

-

-

-

-

-

s

0 s to 359940 s

-

-

-

Duration for which multifunction relay is activated for timer

-

MltFncSw.Tmr.TmCtlOn

40611

2

U32

TAGLIST

RW Warnung vor zyklischem Beschreiben

-

-

-

-

-

-

-

-

1189: daily (IntvDy)

2622: Once (IntvOc)

2623: Weekly (IntvWk)

-

-

-

Repeat cycle time of relay control for timer

-

MltFncSw.Tmr.TmCtlCyc

40613

2

U32

TAGLIST

RW Warnung vor zyklischem Beschreiben

-

-

-

-

-

-

-

-

1189: daily (IntvDy)

2622: Once (IntvOc)

2623: Weekly (IntvWk)

-

-

-

Repeat cycle time of relay control for timer

-

MltFncSw.Tmr.TmCtlCyc

40575

2

U32

TAGLIST

RW Warnung vor zyklischem Beschreiben

-

-

-

-

-

-

-

-

303: Off (Off)

308: On (On)

2632: Automatic generator request (AutoGn)

2633: 1-stage load shedding (LodShdMod)

2634: 1-stage load shedding or 1st stage with 2-stage load shedding (LodShd1Mod)

2635: 1st stage with 2-stage load shedding (LodShd2Mod)

2636: Timer 1 (Tmr1)

2637: Timer 2 (Tmr2)

2638: Control of add. loads (AuxLodCtl)

2639: Relay on if generator running (GnSwOn)

2640: Relay on if ext. source available (ExSrcSwOn)

2641: Relay on if grid is available (PubGriSwOn)

2642: Relay off in case of fault (FltSwOff)

2643: Relay on in case of warning (WrnSwOn)

2644: Relay on if cluster running (CltSwOn)

2645: Battery compartment fan (BatFanCtl)

2646: Electrolyte pump (EltPmpCtl)

2647: ComSync (ComSyn)

2648: Relay on with power limitation (DrtSwOn)

2649: Network disconnect in emer op (BckModDscon)

2650: Earthing in emer op (BckModGnd)

2900: Battery fan in Multicluster (MccBatFanCtl)

2901: Load shedding in Multicluster (MccLodShd)

3910: Redundant grid disconnection control (RdtBckModDscon)

-

-

-

Operating mode of multifunction relay

Mlt.OpMode

MltFncSw.OpMode

40577

2

U32

TAGLIST

RW Warnung vor zyklischem Beschreiben

-

-

-

-

-

-

-

-

303: Off (Off)

308: On (On)

2632: Automatic generator request (AutoGn)

2633: 1-stage load shedding (LodShdMod)

2634: 1-stage load shedding or 1st stage with 2-stage load shedding (LodShd1Mod)

2635: 1st stage with 2-stage load shedding (LodShd2Mod)

2636: Timer 1 (Tmr1)

2637: Timer 2 (Tmr2)

2638: Control of add. loads (AuxLodCtl)

2639: Relay on if generator running (GnSwOn)

2640: Relay on if ext. source available (ExSrcSwOn)

2641: Relay on if grid is available (PubGriSwOn)

2642: Relay off in case of fault (FltSwOff)

2643: Relay on in case of warning (WrnSwOn)

2644: Relay on if cluster running (CltSwOn)

2645: Battery compartment fan (BatFanCtl)

2646: Electrolyte pump (EltPmpCtl)

2647: ComSync (ComSyn)

2648: Relay on with power limitation (DrtSwOn)

2649: Network disconnect in emer op (BckModDscon)

2650: Earthing in emer op (BckModGnd)

2900: Battery fan in Multicluster (MccBatFanCtl)

2901: Load shedding in Multicluster (MccLodShd)

3910: Redundant grid disconnection control (RdtBckModDscon)

-

-

-

Operating mode of multifunction relay

Mlt.OpMode

MltFncSw.OpMode

40587

2

U32

TAGLIST

RW Warnung vor zyklischem Beschreiben

-

-

-

-

-

-

-

-

303: Off (Off)

308: On (On)

2632: Automatic generator request (AutoGn)

2633: 1-stage load shedding (LodShdMod)

2634: 1-stage load shedding or 1st stage with 2-stage load shedding (LodShd1Mod)

2635: 1st stage with 2-stage load shedding (LodShd2Mod)

2636: Timer 1 (Tmr1)

2637: Timer 2 (Tmr2)

2638: Control of add. loads (AuxLodCtl)

2639: Relay on if generator running (GnSwOn)

2640: Relay on if ext. source available (ExSrcSwOn)

2641: Relay on if grid is available (PubGriSwOn)

2642: Relay off in case of fault (FltSwOff)

2643: Relay on in case of warning (WrnSwOn)

2644: Relay on if cluster running (CltSwOn)

2645: Battery compartment fan (BatFanCtl)

2646: Electrolyte pump (EltPmpCtl)

2647: ComSync (ComSyn)

2648: Relay on with power limitation (DrtSwOn)

2649: Network disconnect in emer op (BckModDscon)

2650: Earthing in emer op (BckModGnd)

2900: Battery fan in Multicluster (MccBatFanCtl)

2901: Load shedding in Multicluster (MccLodShd)

3910: Redundant grid disconnection control (RdtBckModDscon)

-

-

-

Slave 1: Operating mode of multifunction relay

-

MltFncSw.OpModeSlv1

40589

2

U32

TAGLIST

RW Warnung vor zyklischem Beschreiben

-

-

-

-

-

-

-

-

303: Off (Off)

308: On (On)

2632: Automatic generator request (AutoGn)

2633: 1-stage load shedding (LodShdMod)

2634: 1-stage load shedding or 1st stage with 2-stage load shedding (LodShd1Mod)

2635: 1st stage with 2-stage load shedding (LodShd2Mod)

2636: Timer 1 (Tmr1)

2637: Timer 2 (Tmr2)

2638: Control of add. loads (AuxLodCtl)

2639: Relay on if generator running (GnSwOn)

2640: Relay on if ext. source available (ExSrcSwOn)

2641: Relay on if grid is available (PubGriSwOn)

2642: Relay off in case of fault (FltSwOff)

2643: Relay on in case of warning (WrnSwOn)

2644: Relay on if cluster running (CltSwOn)

2645: Battery compartment fan (BatFanCtl)

2646: Electrolyte pump (EltPmpCtl)

2647: ComSync (ComSyn)

2648: Relay on with power limitation (DrtSwOn)

2649: Network disconnect in emer op (BckModDscon)

2650: Earthing in emer op (BckModGnd)

2900: Battery fan in Multicluster (MccBatFanCtl)

2901: Load shedding in Multicluster (MccLodShd)

3910: Redundant grid disconnection control (RdtBckModDscon)

-

-

-

Slave 1: Operating mode of multifunction relay

-

MltFncSw.OpModeSlv1

40599

2

U32

TAGLIST

RW Warnung vor zyklischem Beschreiben

-

-

-

-

-

-

-

-

303: Off (Off)

308: On (On)

2632: Automatic generator request (AutoGn)

2633: 1-stage load shedding (LodShdMod)

2634: 1-stage load shedding or 1st stage with 2-stage load shedding (LodShd1Mod)

2635: 1st stage with 2-stage load shedding (LodShd2Mod)

2636: Timer 1 (Tmr1)

2637: Timer 2 (Tmr2)

2638: Control of add. loads (AuxLodCtl)

2639: Relay on if generator running (GnSwOn)

2640: Relay on if ext. source available (ExSrcSwOn)

2641: Relay on if grid is available (PubGriSwOn)

2642: Relay off in case of fault (FltSwOff)

2643: Relay on in case of warning (WrnSwOn)

2644: Relay on if cluster running (CltSwOn)

2645: Battery compartment fan (BatFanCtl)

2646: Electrolyte pump (EltPmpCtl)

2647: ComSync (ComSyn)

2648: Relay on with power limitation (DrtSwOn)

2649: Network disconnect in emer op (BckModDscon)

2650: Earthing in emer op (BckModGnd)

2900: Battery fan in Multicluster (MccBatFanCtl)

2901: Load shedding in Multicluster (MccLodShd)

3910: Redundant grid disconnection control (RdtBckModDscon)

-

-

-

Slave 2: Operating mode of multifunction relay

-

MltFncSw.OpModeSlv2

40601

2

U32

TAGLIST

RW Warnung vor zyklischem Beschreiben

-

-

-

-

-

-

-

-

303: Off (Off)

308: On (On)

2632: Automatic generator request (AutoGn)

2633: 1-stage load shedding (LodShdMod)

2634: 1-stage load shedding or 1st stage with 2-stage load shedding (LodShd1Mod)

2635: 1st stage with 2-stage load shedding (LodShd2Mod)

2636: Timer 1 (Tmr1)

2637: Timer 2 (Tmr2)

2638: Control of add. loads (AuxLodCtl)

2639: Relay on if generator running (GnSwOn)

2640: Relay on if ext. source available (ExSrcSwOn)

2641: Relay on if grid is available (PubGriSwOn)

2642: Relay off in case of fault (FltSwOff)

2643: Relay on in case of warning (WrnSwOn)

2644: Relay on if cluster running (CltSwOn)

2645: Battery compartment fan (BatFanCtl)

2646: Electrolyte pump (EltPmpCtl)

2647: ComSync (ComSyn)

2648: Relay on with power limitation (DrtSwOn)

2649: Network disconnect in emer op (BckModDscon)

2650: Earthing in emer op (BckModGnd)

2900: Battery fan in Multicluster (MccBatFanCtl)

2901: Load shedding in Multicluster (MccLodShd)

3910: Redundant grid disconnection control (RdtBckModDscon)

-

-

-

Slave 2: Operating mode of multifunction relay

-

MltFncSw.OpModeSlv2

31049

2

U32

TAGLIST

RO

-

-

-

-

-

-

-

-

303: Off (Off)

308: On (On)

16777213: Information not available (NaNStt)

-

-

-

Slave 1: Multifunction relay status

-

MltFncSw.SttSlv1

31413

2

U32

TAGLIST

RO

-

-

-

-

-

-

-

-

303: Off (Off)

308: On (On)

16777213: Information not available (NaNStt)

-

-

-

Slave 1: Multifunction relay status

-

MltFncSw.SttSlv1

31051

2

U32

TAGLIST

RO

-

-

-

-

-

-

-

-

303: Off (Off)

308: On (On)

16777213: Information not available (NaNStt)

-

-

-

Slave 2: Multifunction relay status

-

MltFncSw.SttSlv2

31415

2

U32

TAGLIST

RO

-

-

-

-

-

-

-

-

303: Off (Off)

308: On (On)

16777213: Information not available (NaNStt)

-

-

-

Slave 2: Multifunction relay status

-

MltFncSw.SttSlv2

40063

2

U32

FW

RO

-

-

-

-

-

-

-

-

0  to 4294967294 

0 

-

-

Firmware version of the main processor

HP.swRev

Nameplate.CmpMain.SwRev

40065

2

U32

FW

RO

-

-

-

-

-

-

-

-

0  to 4294967294 

0 

-

-

Firmware version of the logic component

CPLD.swRev

Nameplate.CmpSigProc.SwRev

40789

2

U32

REV

RO

-

-

-

-

-

-

-

-

0  to 4294967294 

0 

-

-

Communication version

ComRev

Nameplate.ComRev

40631

12

STR32

UTF8

RW Warnung vor zyklischem Beschreiben

-

-

-

-

-

-

-

-

-

-

-

-

-

-

Nameplate.Location

40497

16

STR32

UTF8

RO

40076

MAC

11

4

uint64

-

RO

-

-

-

-

-

-

-

Nameplate.MacId

30051

2

U32

TAGLIST

RO

-

-

-

-

-

-

-

-

8007: Battery Inverter (DevClss7)

1

-

-

Device class

MainModel

Nameplate.MainModel

30053

2

U32

TAGLIST

RO

40240
40037

DERTyp
Opt

120
1

1
8

uint16
string8

-

RO
RO

-

9332: Sunny Island 4.4M (SI 4.4M)

9333: Sunny Island 6.0H (SI 6.0H)

9334: Sunny Island 8.0H (SI 8.0H)

9474: SI4.4M-13 (SI4.4M-13)

9475: SI6.0H-13 (SI6.0H-13)

9476: SI8.0H-13 (SI8.0H-13)

1

-

-

Device type

Model

Nameplate.Model

30059

2

U32

FW

RO

40045

Vr

1

8

string8

-

RO

-

0  to 4294967294 

0 

-

-

Software package

Pkg.swRev

Nameplate.PkgRev

30057

2

U32

RAW

RO

-

-

-

-

-

-

-

-

0  to 4294967294 

0 

-

-

Serial number

SerNumSet, Serial Number, SerialNumber

Nameplate.SerNum

40067

2

U32

RAW

RO

40053

SN

1

16

string16

-

RO

-

0  to 4294967294 

0 

-

-

Serial number

SerNumSet, Serial Number, SerialNumber

Nameplate.SerNum

40783

2

U32

RAW

RO

-

-

-

-

-

-

-

-

0  to 4294967294 

-

-

-

Serial no. Slave1 (Phase L2)

-

Nameplate.SerNum.Slv1

40785

2

U32

RAW

RO

-

-

-

-

-

-

-

-

0  to 4294967294 

-

-

-

Serial no. Slave2 (Phase L3)

-

Nameplate.SerNum.Slv2

40745

2

U32

TAGLIST

RW Warnung vor zyklischem Beschreiben

-

-

-

-

-

-

-

-

2626: Fixed limit value for current limitation (ValALimMod)

2627: Frequency-dependent current limitation (HzALimMod)

-

-

-

Limitation type of generator current

-

Operation.ALimMod

40675

2

U32

TAGLIST

RW Warnung vor zyklischem Beschreiben

-

-

-

-

-

-

-

-

303: Off (Off)

308: On (On)

-

-

-

Automatic frequency control

-

Operation.AutoHzCtl

41277

2

U32

HIDDEN

RW Warnung vor zyklischem Beschreiben

-

-

-

-

-

-

-

-

381: Stop (Stop)

3660: New system (NewSys)

3661: New battery (NewBat)

3664: Emergency charge mode (EmgCha)

-

-

-

QCG Start

-

Operation.Cfg.QCG

40787

2

U32

TAGLIST

RW Warnung vor zyklischem Beschreiben

-

-

-

-

-

-

-

-

2612: Further operation (CtnOp)

2613: Stop all devices (StopAllDev)

-

-

-

Cluster behaviour when a device fails

-

Operation.CltFltMod

40567

2

U32

Dauer

RW Warnung vor zyklischem Beschreiben

-

-

-

-

-

-

-

s

0 s to 3600 s

-

-

-

Cooling down time of generator

-

Operation.CoolTm

30877

2

U32

TAGLIST

RO

-

-

-

-

-

-

-

-

303: Off (Off)

1461: Mains connected (GriConn)

1462: Backup not available (GriConnNoBck)

1463: Backup (Bck)

16777213: Information not available (NaNStt)

-

-

-

Power supply status

-

Operation.CsmpGriConnStt

30915

2

U32

TAGLIST

RO

-

-

-

-

-

-

-

-

303: Off (Off)

1461: Mains connected (GriConn)

1462: Backup not available (GriConnNoBck)

1463: Backup (Bck)

16777213: Information not available (NaNStt)

-

-

-

Power supply status

-

Operation.CsmpGriConnStt

40805

2

U32

TAGLIST

WO

-

-

-

-

-

-

-

-

303: Off (Off)

308: On (On)

-

-

Anlagensteuerobjekt

Energy saving mode

-

Operation.EnSavMod

30211

2

U32

TAGLIST

RO

-

-

-

-

-

-

-

-

336: Contact manufacturer (PrioA)

337: Contact installer (PrioC)

338: invalid (PrioIna)

887: none (NonePrio)

3 

-

-

Recommended action

Op.Prio

Operation.Evt.Prio

30213

2

U32

TAGLIST

RO

-

-

-

-

-

-

-

-

886: none (NoneMsg)

30213: Für Fehlerbeschreibung siehe SMA Registeradresse 30247; 30247: Beschreibung der Ereignismeldung siehe Anleitung des Produkts

-

-

-

Message

-

Operation.Evt.Msg

30215

2

U32

TAGLIST

RO

-

-

-

-

-

-

-

-

885: none (NoneDsc)

-

-

-

Fault correction measure

-

Operation.Evt.Dsc

30559

2

U32

FIX0

RO

-

-

-

-

-

-

-

-

-

-

-

-

Number of events for user

Op.EvtCntUsr

Operation.EvtCntUsr

35377

4

U64

FIX0

RO

-

-

-

-

-

-

-

-

-

-

-

-

Number of events for user

Op.EvtCntUsr

Operation.EvtCntUsr

30561

2

U32

FIX0

RO

-

-

-

-

-

-

-

-

-

-

-

-

Number of events for installer

Op.EvtCntIstl

Operation.EvtCntIstl

35381

4

U64

FIX0

RO

-

-

-

-

-

-

-

-

-

-

-

-

Number of events for installer

Op.EvtCntIstl

Operation.EvtCntIstl

30563

2

U32

FIX0

RO

-

-

-

-

-

-

-

-

-

-

-

-

Number of events for service

Op.EvtCntSvc

Operation.EvtCntSvc

35385

4

U64

FIX0

RO

-

-

-

-

-

-

-

-

-

-

-

-

Number of events for service

Op.EvtCntSvc

Operation.EvtCntSvc

30247

2

U32

FIX0

RO

40690
40670
40650
40628
40226

DCEvt
DCEvt
DCEvt
Evt
Evt1

160
160
160
160
101

2
2
2
2
2

uint32
uint32
uint32
uint32
uint32

-

RO
RO
RO
RO
RO

-

30213: Für Fehlerbeschreibung siehe SMA Registeradresse 30247; 30247: Beschreibung der Ereignismeldung siehe Anleitung des Produkts

-

-

-

Current event number for manufacturer

Op.EvtNoDvlp

Operation.Evt.EvtNo

40141

2

U32

FIX0

RW Warnung vor zyklischem Beschreiben

-

-

-

-

-

-

-

-

0  to 10 

-

-

-

Max. start attempts after error

-

Operation.FltRstrMaxCnt

40569

2

U32

Dauer

RW Warnung vor zyklischem Beschreiben

-

-

-

-

-

-

-

s

0 s to 86400 s

-

-

-

Idle period after generator fault

-

Operation.FltStopTm

30879

2

U32

TAGLIST

RO

-

-

-

-

-

-

-

-

46: Battery (Bat)

1773: No request (NotDmd)

1774: Load (Lod)

1775: Time control (TmCtl)

1776: Manual one hour (Man1h)

1777: Manual start (ManStr)

1778: External source (ExSrc)

16777213: Information not available (NaNStt)

-

-

-

Reason for generator request

-

Operation.GnDmdReas

40747

2

U32

TAGLIST

RW Warnung vor zyklischem Beschreiben

-

-

-

-

-

-

-

-

2628: Low (LowMod)

2629: Medium (MedMod)

2630: Normal (NrmMod)

2631: High (HiMod)

-

-

-

Sensitivity of generator failure detection

-

Operation.GnFltDet

40071

2

U32

TAGLIST

RW Warnung vor zyklischem Beschreiben

-

-

-

-

-

-

-

-

1799: No (NoneSrc)

1800: Generator (GnSrc)

1801: Mains (GriSrc)

1802: Mains and generator (GriGnSrc)

-

-

-

Grid creating generator

-

Operation.GriCreaSrc

30599

2

U32

FIX0

RO

-

-

-

-

-

-

-

-

-

-

-

-

Number of grid connections

Op.GriSwCnt

Operation.GriSwCnt

30203

2

U32

FIX0

RO

-

-

-

-

-

-

-

W

0 W to 1 W

0 W

-

-

Nominal power in Ok Mode

-

Operation.HealthStt.Ok

31085

2

U32

FIX0

RO

-

-

-

-

-

-

-

W

0 W to 1 W

0 W

-

-

Nominal power in Ok Mode

-

Operation.HealthStt.Ok

30205

2

U32

FIX0

RO

-

-

-

-

-

-

-

W

0 W to 1 W

0 W

-

-

Nominal power in Warning Mode

-

Operation.HealthStt.Wrn

30207

2

U32

FIX0

RO

-

-

-

-

-

-

-

W

0 W to 1 W

0 W

-

-

Nominal power in Fault Mode

-

Operation.HealthStt.Alm

30201

2

U32

TAGLIST

RO

-

-

-

-

-

-

-

-

35: Fault (Alm)

303: Off (Off)

307: Ok (Ok)

455: Warning (Wrn)

2 

-

-

Condition

Op.Health

Operation.Health

31015

2

U32

TAGLIST

RO

-

-

-

-

-

-

-

-

35: Fault (Alm)

303: Off (Off)

307: Ok (Ok)

455: Warning (Wrn)

-

-

-

Operating status Master (Phase L1)

-

Operation.Health.Master

31053

2

U32

TAGLIST

RO

-

-

-

-

-

-

-

-

35: Fault (Alm)

303: Off (Off)

307: Ok (Ok)

455: Warning (Wrn)

-

-

-

Operating status Slave1 (Phase L2)

-

Operation.Health.Slv1

31055

2

U32

TAGLIST

RO

-

-

-

-

-

-

-

-

35: Fault (Alm)

303: Off (Off)

307: Ok (Ok)

455: Warning (Wrn)

-

-

-

Operating status Slave2 (Phase L3)

-

Operation.Health.Slv2

40573

2

U32

FIX2

RW Warnung vor zyklischem Beschreiben

-

-

-

-

-

-

-

Hz

-

-

-

-

Generator nominal frequency

-

Operation.HzRtg

40563

2

U32

Dauer

RW Warnung vor zyklischem Beschreiben

-

-

-

-

-

-

-

s

0 s to 21600 s

-

-

-

Average operating time of generator

-

Operation.MinRunTm

40565

2

U32

Dauer

RW Warnung vor zyklischem Beschreiben

-

-

-

-

-

-

-

s

0 s to 21600 s

-

-

-

Average idle period of generator

-

Operation.MinStopTm

40009

2

U32

TAGLIST

RW Warnung vor zyklischem Beschreiben

-

-

-

-

-

-

-

-

381: Stop (Stop)

1467: Start (Str)

-

-

-

General operating mode

Op.OpModSet

Operation.OpMod

30881

2

U32

TAGLIST

RO

40302

ECPConn

122

1

uint16

-

RO

-

1779: Separated (Dscon)

1780: Public electricity mains (PubGri)

1781: Island mains (IsoGri)

16777213: Information not available (NaNStt)

-

-

-

Plant mains connection

-

Operation.PvGriConn

41279

2

U32

HIDDEN

RW Warnung vor zyklischem Beschreiben

-

-

-

-

-

-

-

-

381: Stop (Stop)

3660: New system (NewSys)

3661: New battery (NewBat)

3664: Emergency charge mode (EmgCha)

16777213: Information not available (NaNStt)

-

-

-

QCG status

-

Operation.QCGStt

30199

2

U32

Dauer

RO

-

-

-

-

-

-

-

s

-

-

-

-

Waiting time until feed-in

Op.TmsRmg

Operation.RmgTms

40627

2

U32

Dauer

RW Warnung vor zyklischem Beschreiben

-

-

-

-

-

-

-

s

0 s to 359940 s

-

-

-

Operating time for time-controlled inverter op.

-

Operation.TmCtl.ActTm

40623

2

U32

TAGLIST

RW Warnung vor zyklischem Beschreiben

-

-

-

-

-

-

-

-

1129: Yes (Yes)

1130: No (No)

-

-

-

Time-controlled inverter operation

-

Operation.TmCtl.IsOn

40625

2

U32

DT

RW Warnung vor zyklischem Beschreiben

-

-

-

-

-

-

-

-

1293840000  to 4102444799 

-

-

-

Start date for time-controlled inverter operation

-

Operation.TmCtl.StrTm

40629

2

U32

TAGLIST

RW Warnung vor zyklischem Beschreiben

-

-

-

-

-

-

-

-

1189: daily (IntvDy)

2622: Once (IntvOc)

2623: Weekly (IntvWk)

-

-

-

Repeat cycle for time-controlled inverter op.

-

Operation.TmCtl.RptCyc

31013

2

U32

Dauer

RO

-

-

-

-

-

-

-

s

-

-

-

-

Remaining min. operating time of generator

-

Operation.RmgMinRunTm

40571

2

U32

Dauer

RW Warnung vor zyklischem Beschreiben

-

-

-

-

-

-

-

s

5 s to 900 s

-

-

-

Warm-up time of generator

-

Operation.WrmTm

41217

2

U32

FIX0

RW Warnung vor zyklischem Beschreiben

-

-

-

-

-

-

-

W

0 W to 500000 W

-

-

-

Set active power limit at grid connection point

-

PCC.WMax

41199

2

U32

FIX0

RW Warnung vor zyklischem Beschreiben

-

-

-

-

-

-

-

%

0 % to 100 %

100 %

-

-

Set active power limit at grid connection point

-

PCC.WMaxNom

41203

2

U32

FIX0

RW Warnung vor zyklischem Beschreiben

-

-

-

-

-

-

-

W

0 W to 500000 W

2500 W

-

-

Nominal PV system power

-

Plnt.DcWRtg

40713

2

U32

FIX1

RW Warnung vor zyklischem Beschreiben

-

-

-

-

-

-

-

%

0 % to 70 %

-

-

-

Battery state of charge for protection mode

-

ProMod.ChaSttLim

41271

2

U32

FIX1

RW Warnung vor zyklischem Beschreiben

-

-

-

-

-

-

-

%

0 % to 70 %

-

-

-

Battery state of charge for protection mode

-

ProMod.ChaSttLim

41273

2

U32

FIX1

RW Warnung vor zyklischem Beschreiben

-

-

-

-

-

-

-

%

0 % to 70 %

-

-

-

Battery state of charge for protection mode

-

ProMod.ChaSttLim

40709

2

U32

TM

RW Warnung vor zyklischem Beschreiben

-

-

-

-

-

-

-

-

0  to 86399 

-

-

-

Start time of battery protection mode level

-

ProMod.StrTm

40711

2

U32

TM

RW Warnung vor zyklischem Beschreiben

-

-

-

-

-

-

-

-

0  to 86399 

-

-

-

End time of battery protection mode level

-

ProMod.StopTm

40677

2

U32

FIX3

RW Warnung vor zyklischem Beschreiben

-

-

-

-

-

-

-

A

-

-

-

-

Maximum current from public grid

-

PubGri.ExtGriAMax

40679

2

U32

TAGLIST

RW Warnung vor zyklischem Beschreiben

-

-

-

-

-

-

-

-

1129: Yes (Yes)

1130: No (No)

-

-

-

Power feedback to public grid allowed

-

PubGri.FeedPerm

40697

2

U32

FIX0

RW Warnung vor zyklischem Beschreiben

-

-

-

-

-

-

-

W

-

-

-

-

Maximum network reverse power

-

PubGri.PwrMon.RvPwrMax

40699

2

U32

Dauer

RW Warnung vor zyklischem Beschreiben

-

-

-

-

-

-

-

s

0 s to 60 s

-

-

-

Maximum network reverse power tripping time

-

PubGri.PwrMon.RvPwrMaxTms

40681

2

U32

TAGLIST

RW Warnung vor zyklischem Beschreiben

-

-

-

-

-

-

-

-

1129: Yes (Yes)

1130: No (No)

-

-

-

Network request via battery state of charge switched on

-

PubGri.GriDmdBatCha.IsOn

40683

2

U32

FIX0

RW Warnung vor zyklischem Beschreiben

-

-

-

-

-

-

-

%

-

-

-

-

Lmt battery state of charge for connection to grid

-

PubGri.GriDmdBatCha.OnLim

40685

2

U32

FIX0

RW Warnung vor zyklischem Beschreiben

-

-

-

-

-

-

-

%

-

-

-

-

Lmt battery state of charge for disconnection from grid

-

PubGri.GriDmdBatCha.OffLim

40687

2

U32

TM

RW Warnung vor zyklischem Beschreiben

-

-

-

-

-

-

-

-

0  to 86399 

-

-

-

Start time additional time range grid request

-

PubGri.GriDmdBatCha.AddTm.StrTm

40689

2

U32

TM

RW Warnung vor zyklischem Beschreiben

-

-

-

-

-

-

-

-

0  to 86399 

-

-

-

Start interval for network request

-

PubGri.GriDmdBatCha.AddTm.StopTm

40691

2

U32

FIX0

RW Warnung vor zyklischem Beschreiben

-

-

-

-

-

-

-

%

-

-

-

-

Limit battery state of charge for connect to grid in add time range

-

PubGri.GriDmdBatCha.AddTm.OnLim

40693

2

U32

FIX0

RW Warnung vor zyklischem Beschreiben

-

-

-

-

-

-

-

%

-

-

-

-

Limit battery state of charge for disconnect from grid in add time range

-

PubGri.GriDmdBatCha.AddTm.OffLim

40521

2

U32

TAGLIST

RW Warnung vor zyklischem Beschreiben

-

-

-

-

-

-

-

-

1129: Yes (Yes)

1130: No (No)

-

-

-

Network request via power switched on

-

PubGri.GriDmdW.IsOn

40523

2

U32

FIX0

RW Warnung vor zyklischem Beschreiben

-

-

-

-

-

-

-

W

-

-

-

-

Network request switch-on power limit

-

PubGri.GriDmdW.WOn

40525

2

U32

FIX0

RW Warnung vor zyklischem Beschreiben

-

-

-

-

-

-

-

W

-

-

-

-

Network request switch-off power limit

-

PubGri.GriDmdW.WOff

40527

2

U32

TAGLIST

RW Warnung vor zyklischem Beschreiben

-

-

-

-

-

-

-

-

381: Stop (Stop)

1438: Automatic (Auto)

1467: Start (Str)

-

-

-

Manual control of network connection

-

PubGri.ManCtl

40529

2

U32

TAGLIST

RW Warnung vor zyklischem Beschreiben

-

-

-

-

-

-

-

-

303: Off (Off)

1736: Full and equalization charge (FulEqCha)

1768: Full charge (FulCha)

1769: Equalization charge (EqCha)

-

-

-

Network request via charge type

-

PubGri.GriDmdChaMod.ChaMod

30883

2

U32

TAGLIST

RO

-

-

-

-

-

-

-

-

35: Fault (Alm)

303: Off (Off)

1394: Waiting for valid AC grid (WaitGri)

1466: Wait (Wait)

1787: Initialization (Init)

2183: Mains oper. without feed back (GriConnNoFeed)

2184: Energy saving in the network (EnSavGri)

2185: End energy saving in the network (EnSavStop)

2186: Start energy saving in the network (EnSavStr)

3068: Mains operation with feedback (GriConnFeed)

16777213: Information not available (NaNStt)

-

-

-

Status of utility grid

-

PubGri.Stt

40075

2

U32

TAGLIST

RW Warnung vor zyklischem Beschreiben

-

-

-

-

-

-

-

-

1129: Yes (Yes)

1130: No (No)

-

-

-

Rise in self-consumption switched on

-

SelfCsmp.SelfCsmpIncIsOn

40695

2

U32

TAGLIST

RW Warnung vor zyklischem Beschreiben

-

-

-

-

-

-

-

-

1129: Yes (Yes)

1130: No (No)

-

-

-

Energy saving mode switched on

-

SltMod.IsOn

40703

2

U32

Dauer

RW Warnung vor zyklischem Beschreiben

-

-

-

-

-

-

-

s

3600 s to 604800 s

-

-

-

Maximum duration of energy saving mode

-

SltMod.SltTrcChaTm

40701

2

U32

Dauer

RW Warnung vor zyklischem Beschreiben

-

-

-

-

-

-

-

s

3600 s to 172800 s

-

-

-

Time until change-over to energy saving mode

-

SltMod.TrcChaSltTm

30929

2

U32

TAGLIST

RO

40075

St

11

1

uint16

-

RO

-

35: Fault (Alm)

307: Ok (Ok)

455: Warning (Wrn)

1725: No connection (NotConn)

4 

-

-

Speedwire connection status of SMACOM A

-

Spdwr.ComSocA.Stt

30925

2

U32

TAGLIST

RO

40073

Spd

11

1

uint16

-

RO

-

1720: 10 Mbit/s (ConnSpd10)

1721: 100 Mbit/s (ConnSpd100)

3581: No connection speed set (ConnSpdNone)

3 

-

-

Connection speed of SMACOM A

-

Spdwr.ComSocA.ConnSpd

30927

2

U32

TAGLIST

RO

40074

CfgSt

11

1

uint16

-

RO

-

1726: Half duplex (HalfDpx)

1727: Full duplex (FulDpx)

3582: No duplex mode set (DpxModNone)

3 

-

-

Duplex mode of SMACOM A

-

Spdwr.ComSocA.DpxMode

31017

8

STR32

UTF8

RO

-

-

-

-

-

-

-

-

-

-

-

-

-

-

Spdwr.ActlIp

31025

8

STR32

UTF8

RO

-

-

-

-

-

-

-

-

-

-

-

-

-

-

Spdwr.ActlSnetMsk

31033

8

STR32

UTF8

RO

-

-

-

-

-

-

-

-

-

-

-

-

-

-

Spdwr.ActlGwIp

31041

8

STR32

UTF8

RO

-

-

-

-

-

-

-

-

-

-

-

-

-

-

Spdwr.ActlDnsSrvIp

40157

2

U32

TAGLIST

RW Warnung vor zyklischem Beschreiben

40095

Cfg

12

1

uint16

-

RW Warnung vor zyklischem Beschreiben

-

1129: Yes (Yes)

1130: No (No)

1

-

-

Automatic speedwire configureation switched on

-

Spdwr.AutoCfgIsOn

40159

8

STR32

IP4

RW Warnung vor zyklischem Beschreiben

40097

Addr

12

8

string8

-

RW Warnung vor zyklischem Beschreiben

-

-

-

-

-

-

-

Spdwr.Ip

40167

8

STR32

IP4

RW Warnung vor zyklischem Beschreiben

40105

Msk

12

8

string8

-

RW Warnung vor zyklischem Beschreiben

-

-

-

-

-

-

-

Spdwr.SnetMsk

40175

8

STR32

IP4

RW Warnung vor zyklischem Beschreiben

40113

Gw

12

8

string8

-

RW Warnung vor zyklischem Beschreiben

-

-

-

-

-

-

-

Spdwr.GwIp

40513

8

STR32

IP4

RW Warnung vor zyklischem Beschreiben

40121

DNS1

12

8

string8

-

RW Warnung vor zyklischem Beschreiben

-

-

-

-

-

-

-

Spdwr.DnsSrvIp

40531

2

U32

TAGLIST

RO

-

-

-

-

-

-

-

-

302: ------- (None)

2609: Multicluster Box 6 (MltBox6)

2610: Multicluster Box 12 (MltBox12)

2611: Multicluster Box 36 (MltBox36)

9323: Multicluster Box 12-2 (MltBox12-2)

-

-

-

Type of AC subdistribution

-

Sys.AcTyp

40743

2

U32

TAGLIST

RW Warnung vor zyklischem Beschreiben

-

-

-

-

-

-

-

-

2619: AC sources and DC charge controllers (AcSrcChaReg)

2620: Other DC charge controllers (OthChaReg)

2621: Communicatively coupled DC charge controller (ComChaReg)

-

-

-

Type of additional DC sources

-

Sys.AuxDcTyp

40077

2

U32

FUNKTION_SEC

RW Warnung vor zyklischem Beschreiben

-

-

-

-

-

-

-

-

1146: Execute (Do)

-

-

-

Initiate device restart

DeviceReset,DevRs

Sys.DevRstr